FaCT Canada
Lactate Pro | Portamon NIRS | Barefoot Science | SpiroTiger | Tacx Trainers | Pulse Oximeters | Sensorize Motion Analysis
Polar | Timex | Hosand Telemetry | Fitmate Pro | Bioharness | Biacorpus Body Comp | PhysioFlow | PowerCranks | Spirometer
Home
Who We Are
Test Centers
Price List
Sale Items
Links
FaCT Forum
Our BlogSpot
Site Map
Contact Us

View Cart

Zephyr BioHarness™

BioHarness is a state-of-the-art lightweight portable biological data logger and telemetry system. It monitors, analyzes and records a variety of physiological parameters. The system operates in RF (Radio Frequency) transmitting mode for live viewing of data or data logging mode. It offers a vital advantage to users in a diverse range of sectors, including academic and research, sports, defense, health and wellness and first responder.

Bioharness System

Zephyr BioharnessBioHarness™ integrates patented Smart Fabric sensor technology into a garment that is comfortable and unobtrusive. It captures comprehensive physiological data on the wearer, eliminating the need for multiple devices. The robust BioHarness™ enables genuine real world monitoring of human performance and condition – giving you a vital advantage.

BioHarness™ applications

BioHarness™ has applications in any field requiring high-level wireless physiological monitoring, including research, training and real-time response situations.

BioHarness™ advantage

Bioharness Radio DongleBioHarness™ can be worn in virtually any environment, from combat situations to the sports field. It maintains performance under extreme activity. Offering fast, accurate collection and analysis of high-quality, in-depth data, BioHarness is the definitive product for physiological monitoring out in the field.

Sports

BioHarness™ offers a critical advantage in boosting performance and preventing injury by measuring improvements in technique and response – both over time and in real time. Remote and group monitoring capability offers greater training options. Ideal for sports such as biathlon, etc.

Health and wellness

Bioharness moduleBioHarness™ enables enhanced preventative care, enables effective tracking of rehabilitation success and provides accurate, quality data for in-patient and ambulatory patient status monitoring.

Academic and research

BioHarness™ enables genuine field-based research – allowing previously unavailable research avenues to be explored, and helps achieve greater insights through analysis of quality, in-depth data.

Product Capabilities (PSM Research)

Data Channels

  • ECG
  • Breathing
  • RR Interval
  • Heart Rate
  • Respiration Rate
  • Skin Temperature
  • Posture
  • Vector Magnitude
  • Peak Acceleration
  • Breathing Wave Amplitude
  • X axis acceleration min
  • X axis acceleration peak
  • Y axis acceleration min
  • Y axis acceleration peak
  • Z axis acceleration peak
  • Z axis acceleration min

Live data viewing features include a variety of selectable waveforms and trend data including:

  • ECG
  • Heart Rate
  • RR Values
  • Respiration
    • Tri-axial accelermeter (X, Y & Z)
    • Activity level
    • Posture (attitude of device in degrees from vertical)

    BioHarness™ benefits

    Simultaneous monitoring of heart rate, breathing rate and depth, skin temperature, activity and posture.
    - Obtain in-depth comprehensive information
    - Eliminates requirement for multiple garments
    - Cost-effective

    Smart Fabric-based, dry contact strap
    - Unobtrusive - no impediment to wearer
    - Comfortable over long periods
    - Washable

    Robust
    - Signal and data quality maintained in extreme movement environments

    Real-time or logged monitoring
    - Allows genuine field-based studies
    - Provides status information for real-time decision making
    - Historical data capture enables new research avenues to be explored

    Wireless data export
    - Wireless data transfer eliminates tethers and performance impediments

    All measurements are collected in one device, in the same format
    - Significant reduction in time to collate information from separate sources
    - Allows cross-measurement analysis
    - All data raw data can be exported to Spreadsheet format for further analysis

    30 days of continuous data storage (480 hours)
    - Enables long-term remote use before analysis

    Eight hour battery life, simple USB charging
    - Enables continuous monitoring of long-duration activities

    Download a Bioharness Brochure

    Software Screen Shot with Comments

    Zephyr Bioharness software screen


    Features

    • SDK Available
    • Monitors heart rate, R-R
    • Single pole ECG trace
    • Monitors breathing rate and relative depth
    • Records local skin temperature for trend analysis
    • Monitors inclination in degrees from horizontal for posture reporting
    • Activity measured in velocity magnitude units over pre-defined epochs for calorific analysis
    • Records 3D acceleration to allow study of loading and perturbation changes
    • Fabric-based, dry contacts are non-restrictive and comfortable
    • Allows quantitative analysis between subjects, activity, situation and time
    • Real time and trend analysis via graphical display
    • Wireless connectivity

    Smart Fabric Strap

    Chest Strap: Adjustable, Velcro® fastening
    Material: Elasticized webbing incorporating Zephyr Smart Fabric sensors
    Width: 50 mm
    Weight: 50 grams
    Size: BioHarness ships with a medium strap (no substitutions). Additional straps are available for individual purchase or in 5 packs (one size) or 50 packs (mix sizes).
             - Extra Small (custom)
             - Small (26" to 32.5")
             - Medium (32.5" to 39")
             - Large (39" to 45.5")
             - Extra Large (custom)
    BioHarness Transmitter/Logger
    Frequency ISM radio band (868 - 929 MHz); Frequency is software configurable for country-specific bands
    Sample Rate 250 Hz Max.
    Memory Capacity ~480 hours
    Transmit Range Up to 100 m, environment and antenna dependent
    Weight 35 grams
    Dimensions 80 x 40 x 15 mm
    Battery Life 
    ~ 5 hours transmitting
    ~ 8 hours logging

    Charging is intelligent - the device cannot be overcharged

      • Quick Charge (90%): 1 hour from fully discharged
      • Full charge (100%): 3 hours from fully discharged

    Operating System: Windows® XP, Vista or Windows 7

    Connectivity: USB


    BioHarness Team System (PSM Training)
    Includes Omnisense Software for live monitoring and post workout analysis.
    Measurement and monitoring of fitness and fatigue via ventilatory threshold detection and heart rate recovery.

     Bioharness Team System

    Bioharness Team System Videos

    BioHarness BlueTooth System Developers Kit also available.
    Download the Bioharness BT brochure.


    Bioharness Systems Pricing and Purchase (Canadian Dollars)

    Bioharness packageBioHarness PSM Research Multi Pack: $1399
    Includes Small, Medium and Large Straps

    PSM Research Second Person Package (No software included): $699
    Includes Module, Charging Cradle, Radio dongle, Medium Strap.

     

    Additional Chest Strap: $45

    Chest Strap Size:

    Bioharness BlueTooth SDK (Software Developers Kit). A non-disclosure agreement must be signed before delivery. Contact us.
    Includes Small, Medium and Large Straps: $849

    Bioharness PSM Training Complete with Omnisense Software for Monitoring and Analysis

    Monitor Heart Rate, Breathing Rate, Posture, Activity Level and Skin Temperature for up to 64 athletes in real time on one computer. Measurement and monitoring of fitness and fatigue via ventilatory threshold detection and heart rate recovery.

    BioHarness PSM Training (Team System) One Person Starter Pack: $599 (Sale Price: Two only)
    Includes Small, Medium and Large Straps

    BioHarness PSM Training 4 Person System: $3299
    Includes 6 Straps, Long Range Antenna and Carrying Case

    BioHarness PSM Training 10 Person System: $4999
    Includes Long Range Antenna, No Case

    Inquire re pricing of Larger Size Team Packs, Additonal Persons and Accessories.

    FaCT Forum | BlogSpot | Site Map | Contact Us